Administrative Regulations on Radio Waves of Industrial, Scientific, Medical Equipment Article 11

The operating frequencies, operating band ranges, and radiation field strength used in ISM equipment shall accord with CNS standards.The radiation field strength of ISM equipment using the following operating frequencies and band ranges is unlimited.-------------------------------------------------------------------------------Operating center frequency Tolerance-------------------------------------------------------------------------------11.1 13,560 kHz................................. ±7.0 kHz11.2 27,120 kHz................................. ±163.0 kHz11.3 40.680MHz................................ ±20.0 kHz11.4 2,450 MHz................................. ±50.0 MHz11.5 5,800 MHz................................. ±75.0 MHz11.6 24,125 MHz...................... ......... ±125.0 MHz----------------------------------------------------------------------------------
中文原文 工業科學醫療用電波輻射性電機管理辦法第11條
工科醫用電機使用之作業頻率與作業頻帶範圍及電波輻射電場強度,應符合中華民國國家標準之規定。
使用下列作業頻率及其作業頻帶範圍之工科醫用電機,其電波輻射電場強度不受限制:
一、作業中心頻率為13560kHz者,其作業頻帶範圍為作業中心頻率加減7kHz。
二、作業中心頻率為27120kHz者,其作業頻帶範圍為作業中心頻率加減163kHz。
三、作業中心頻率為40680kHz者,其作業頻帶範圍為作業中心頻率加減20kHz。
四、作業中心頻率為2450MHz者,其作業頻帶範圍為作業中心頻率加減50MHz。
五、作業中心頻率為5800MHz者,其作業頻帶範圍為作業中心頻率加減75MHz。
六、作業中心頻率為24125MHz者,其作業頻帶範圍為作業中心頻率加減125MHz。