Standards for Air Pollutant Emission from Stationary Pollution Sources Article 13
For those circumstances in which a stationary pollution source establishes facilities for the continuous automatic monitoring of air pollutants in accordance with regulations, the daily measurement values shall comply with the following regulations:I. For monitoring data on particulate pollutant opacity, recorded 6-minute values may not exceed the accumulated time in emissions standards values by over four hours.II. For monitoring data on gaseous pollutants, recorded one hour values may not exceed the accumulated time in emissions standards values by over two hours.In those circumstances in which a stationary pollution source in the foregoing paragraph is submitted to the competent authority for authorization to establish a conversion relationship between particulate pollutant emissions concentration and particulate pollutant opacity, the particulate pollutant opacity of the particulate pollutant emissions standard value conversion may be used as the standard opacity value.
中文原文 固定污染源空氣污染物排放標準第13條
固定污染源依規定設置空氣污染物連續自動監測設施者,其每日量測值應符合左列規定:
一、粒狀污染物不透光率之監測數據,其六分鐘紀錄值高於排放標準值之累積時間不得超過四小時。
二、氣狀污染物之監測數據,其一小時紀錄值高於排放標準值之累積時間不得超過二小時。
前項固定污染源於建立粒狀污染物排放濃度與粒狀污染物不透光率換算關係報經主管機關核可者,得以其粒狀污染物排放標準值換算之粒狀污染物不透光率值為其不透光率標準值。
一、粒狀污染物不透光率之監測數據,其六分鐘紀錄值高於排放標準值之累積時間不得超過四小時。
二、氣狀污染物之監測數據,其一小時紀錄值高於排放標準值之累積時間不得超過二小時。