Small and Medium-Sized Waste Incinerator Dioxin Control and Emission Standards Article 10

Incinerators shall conduct tests of dioxin in emissions pursuant to the following regulations:I. Incinerators with a handling capacity of 4 tons per hour or more that process hazardous industrial waste or infectious medical waste shall conduct at least one regular test per year.II. Incinerators with a handling capacity of less than 4 tons per hour shall conduct regular tests at least once every two years.III. A test plan shall be sent to the local competent authority seven days before a regular test. The results of each test shall be reported to the local competent authority in a test report within 60 days after the test.IV. If stack emission dioxin in two consecutive regular tests meets the emission standard values of Article 5, relevant documentary proof may be submitted to the local competent authority to apply for an adjustment of the test frequency. After the test frequency has been adjusted, it may not be less than once every two years for incinerators with a handling capacity of four tons per hour or more that process hazardous industrial waste or infectious medical waste. The test frequency may not be less than once every three years for incinerators with a handling capacity of less than four tons per hour.However, when the test results of an inspection by the competent authority or the results of a single regular test exceed the emission standard values of Article 5, the competent authority may demand that regular tests be conducted according to the originally determined test frequency.V. Incinerators with a handling capacity of less than 4 tons per hour that burn waste with a chlorine content of less than 0. 015% may submit documentary proof to the local competent authority to apply for exemption from testing.However, when necessary, the competent authority may demand the resumption of testing.
中文原文 中小型廢棄物焚化爐戴奧辛管制及排放標準第10條
焚化爐應依下列規定進行煙道排氣中戴奧辛檢測:
一、焚化爐處理量達四公噸/小時以上、處理有害事業廢棄物或處理感染性醫療廢棄物者,至少每一年應定期檢測一次。
二、焚化爐處理量未達四公噸/小時者,至少每二年應定期檢測一次。
三、於定期檢測前七日應檢送檢測計畫書至當地主管機關,且每次檢測結果應於檢測後六十日內,向當地主管機關提出檢測報告書。
四、若連續二次定期檢測煙道排氣戴奧辛均符合第五條排放標準值,得檢具相關證明文件向當地主管機關申請調整檢測頻率;經調整檢測頻率後,焚化爐處理量達四公噸/小時以上、處理有害事業廢棄物或處理感染性醫療廢棄物者,其檢測頻率不得低於每二年一次;焚化爐處理量未達四公噸/小時者,其檢測頻率不得低於每三年一次。
但經主管機關稽查檢測結果或任一次定期檢測結果超過第五條排放標準值者,主管機關得要求回復至原定之檢測頻率辦理定期檢測。
五、焚化爐處理量未達四公噸/小時,且燃燒處理之廢棄物含氯量低於○‧○一五%者,可檢具證明文件向當地主管機關申請免予檢測。
但必要時,主管機關得重新要求檢測。

English translation for reference only; the Chinese text prevails. Not legal advice.