Regulations for Safety Inspection of Hazardous Machines and Equipment Article 4
These Regulations shall apply to the dangerous devices with capacity as shown below:1. Boilers(1) Steam boilers that have a maximum operating pressure exceeding one (1) kg/c㎡, or a heat transfer area exceeding one (1) ㎡ , which is either equipped with steam pipes open in the atmosphere with inside diameter above 25 mm, or equipped with the U-shape stand pipes with inside diameter above 25 mm , water head above 5 m, and heat transfer area over 3.5 ㎡ ), or that have inside diameter of shell body exceeding 300 mm or the body length exceeding 600 mm.(2) Hot water boiler that other than those heat medium boilers which have the water head above ten (10) m or heat transfer area above eight (8) ㎡ and the operating temperature exceeding the boiling point of the liquid under atmosphere pressure of one (1) ba.(3) Heat medium boilers with head pressure above 10m or transmission acreage above 8㎡.(4) Throughflow-type boilers that( including multi-pipe thoughflow boilers equipped with a cylinder header having inside diameter above 150 mm or equipped with a square header having sectional area above 177c㎡ ) have a maximum operating pressure above ten (10) km/c㎡ , or that (including those equipped with steam separators whose inside diameter over 300mm or those whose insidecapacity over 0.07m3 ) have the heat transfer area above ten (10) ㎡.2. Pressure vessels:(1) Category Ι pressure vessels that have a maximum operating pressure above one (1) km/ c㎡ or internal volume over 0.2 m3.(2) Category Ι pressure vessels that have not only a maximum operating pressure above one ( 1) km/c㎡ but also an inside diameter above 500 mm and alength above 1000 mm.(3) Category Ι pressure vessels that have the product of the maximum pressure ( expressed in km/ c㎡) and the internalvolume (expressed in m3) exceeding 0.2.3. Special equipment for highpressure gases:These special equipment refer to those equipment used for generation and related storage of the high pressure gages, as well as the supporting facilities ( including towers and tanks used for reaction, separation, refining or distillation purpose , where the distance between the highest tangent and lowest tangent of the towers are longer than five (5) m or the capacity of the storage tank is over 300 m3 or 3 tons), that the product of their design pressure ( expressed in km/ c㎡) and internal capacity (expressed in m3) exceeding 0.04. However, the vessels listed below shall be excluded from above category:(1) Vessels relating to pumps, compressors, pressure accumulators, etc.(2) Vessels relating to buffers and other relevant buffering instruments.(3) Vessels relating to flow meters, level gauges and other measuring instruments and filters.(4) Vessels used for the air conditioning equipment.(5) Vessels used for air compressing instruments having gauge pressure below 50 kg/c㎡ under the temperature of 35° C.(6) Vessels usedfor high-pressure vessels.(7) Other vessels designated by the central competent authority.4. Vessels used for high-pressure gases:Except for those vessels listed below, these vessels refer to the vessels that used for containinghigh-pressure gases with the internal capacity over 500 liters, and that can be movablerelative to the ground:(1) Vessels not used in airtight conditions.(2) Vessels used for air compressing instruments having gauge pressure below50 kg/c㎡ under the temperature of 35° C.(3) Others vessels designated by the central competent authority.
中文原文 危險性機械及設備安全檢查規則第4條
本規則適用於下列容量之危險性設備:
一、鍋爐:
(一)最高使用壓力(表壓力,以下同)超過每平方公分一公斤,或傳熱面積超過一平方公尺(裝有內徑二十五公厘以上開放於大氣中之蒸汽管之蒸汽鍋爐、或在蒸汽部裝有內徑二十五公厘以上之U字形豎立管,其水頭壓力超過五公尺之蒸汽鍋爐,為傳熱面積超過三點五平方公尺),或胴體內徑超過三百公厘,長度超過六百公厘之蒸汽鍋爐。
(二)水頭壓力超過十公尺,或傳熱面積超過八平方公尺,且液體使用溫度超過其在一大氣壓之沸點之熱媒鍋爐以外之熱水鍋爐。
(三)水頭壓力超過十公尺,或傳熱面積超過八平方公尺之熱媒鍋爐。
(四)鍋爐中屬貫流式者,其最高使用壓力超過每平方公分十公斤(包括具有內徑超過一百五十公厘之圓筒形集管器,或剖面積超過一百七十七平方公分之方形集管器之多管式貫流鍋爐),或其傳熱面積超過十平方公尺者(包括具有汽水分離器者,其汽水分離器之內徑超過三百公厘,或其內容積超過零點零七立方公尺者)。
二、壓力容器:
(一)最高使用壓力超過每平方公分一公斤,且內容積超過零點二立方公尺之第一種壓力容器。
(二)最高使用壓力超過每平方公分一公斤,且胴體內徑超過五百公厘,長度超過一千公厘之第一種壓力容器。
(三)以「每平方公分之公斤數」單位所表示之最高使用壓力數值與以「立方公尺」單位所表示之內容積數值之積,超過零點二之第一種壓力容器。
三、高壓氣體特定設備:指供高壓氣體之製造(含與製造相關之儲存)設備及其支持構造物(供進行反應、分離、精鍊、蒸餾等製程之塔槽類者,以其最高位正切線至最低位正切線間之長度在五公尺以上之塔,或儲存能力在三百立方公尺或三公噸以上之儲槽為一體之部分為限),其容器以「每平方公分之公斤數」單位所表示之設計壓力數值與以「立方公尺」單位所表示之內容積數值之積,超過零點零四者。
但下列各款容器,不在此限:
(一)泵、壓縮機、蓄壓機等相關之容器。
(二)緩衝器及其他緩衝裝置相關之容器。
(三)流量計、液面計及其他計測機器、濾器相關之容器。
(四)使用於空調設備之容器。
(五)溫度在攝氏三十五度時,表壓力在每平方公分五十公斤以下之空氣壓縮裝置之容器。
(六)高壓氣體容器。
(七)其他經中央主管機關指定者。
四、高壓氣體容器:指供灌裝高壓氣體之容器中,相對於地面可移動,其內容積在五百公升以上者。
但下列各款容器,不在此限:
(一)於未密閉狀態下使用之容器。
(二)溫度在攝氏三十五度時,表壓力在每平方公分五十公斤以下之空氣壓縮裝置之容器。
(三)其他經中央主管機關指定者。
一、鍋爐:
(一)最高使用壓力(表壓力,以下同)超過每平方公分一公斤,或傳熱面積超過一平方公尺(裝有內徑二十五公厘以上開放於大氣中之蒸汽管之蒸汽鍋爐、或在蒸汽部裝有內徑二十五公厘以上之U字形豎立管,其水頭壓力超過五公尺之蒸汽鍋爐,為傳熱面積超過三點五平方公尺),或胴體內徑超過三百公厘,長度超過六百公厘之蒸汽鍋爐。
(二)水頭壓力超過十公尺,或傳熱面積超過八平方公尺,且液體使用溫度超過其在一大氣壓之沸點之熱媒鍋爐以外之熱水鍋爐。
(三)水頭壓力超過十公尺,或傳熱面積超過八平方公尺之熱媒鍋爐。
(四)鍋爐中屬貫流式者,其最高使用壓力超過每平方公分十公斤(包括具有內徑超過一百五十公厘之圓筒形集管器,或剖面積超過一百七十七平方公分之方形集管器之多管式貫流鍋爐),或其傳熱面積超過十平方公尺者(包括具有汽水分離器者,其汽水分離器之內徑超過三百公厘,或其內容積超過零點零七立方公尺者)。
二、壓力容器:
(一)最高使用壓力超過每平方公分一公斤,且內容積超過零點二立方公尺之第一種壓力容器。
(二)最高使用壓力超過每平方公分一公斤,且胴體內徑超過五百公厘,長度超過一千公厘之第一種壓力容器。
(三)以「每平方公分之公斤數」單位所表示之最高使用壓力數值與以「立方公尺」單位所表示之內容積數值之積,超過零點二之第一種壓力容器。
三、高壓氣體特定設備:指供高壓氣體之製造(含與製造相關之儲存)設備及其支持構造物(供進行反應、分離、精鍊、蒸餾等製程之塔槽類者,以其最高位正切線至最低位正切線間之長度在五公尺以上之塔,或儲存能力在三百立方公尺或三公噸以上之儲槽為一體之部分為限),其容器以「每平方公分之公斤數」單位所表示之設計壓力數值與以「立方公尺」單位所表示之內容積數值之積,超過零點零四者。
但下列各款容器,不在此限:
(一)泵、壓縮機、蓄壓機等相關之容器。
(二)緩衝器及其他緩衝裝置相關之容器。
(三)流量計、液面計及其他計測機器、濾器相關之容器。
(四)使用於空調設備之容器。
(五)溫度在攝氏三十五度時,表壓力在每平方公分五十公斤以下之空氣壓縮裝置之容器。
(六)高壓氣體容器。
(七)其他經中央主管機關指定者。
四、高壓氣體容器:指供灌裝高壓氣體之容器中,相對於地面可移動,其內容積在五百公升以上者。
但下列各款容器,不在此限:
(一)於未密閉狀態下使用之容器。
(二)溫度在攝氏三十五度時,表壓力在每平方公分五十公斤以下之空氣壓縮裝置之容器。
(三)其他經中央主管機關指定者。