Standard for Installation of Fire Safety Devices based on Use and Occupancy Article 45

On completion of automatic sprinkler system, pressurization test shall be made pursuant to Article 33. But air compression test shall be made to pipe system of enclosed dry type automatic sprinkler system. During the test, the air pressure remains at 2.8kgf/cm2 or 0.28Mpa for 24 consecutive hours. If the air leakage is less than 0.1kg/cm2 or 0.01Mpa, the product is qualified.
中文原文 各類場所消防安全設備設置標準第45條
自動撒水設備竣工時,應做加壓試驗,其測試方法準用第三十三條規定。
但密閉乾式管系應併行空氣壓試驗,試驗時,應使空氣壓力達到每平方公分二點八公斤或0.28MPa之標準,其壓力持續二十四小時,漏氣減壓量應在每平方公分零點一公斤以下或0.01MPa以下為合格。

English translation for reference only; the Chinese text prevails. Not legal advice.